Rapid monitoring of chlorophyll-a concentration in inland water bodies using a portable proximal sensing technology
Author:
Affiliation:

1.Key Laboratory of Lake and Watershed Science for Water Security,Nanjing Institute of Geography and Limnology,Chinese Academy of Sciences;2.: Key Laboratory of Lake and Watershed Science for Water Security,Nanjing Institute of Geography and Limnology,Chinese Academy of Sciences

Clc Number:

Fund Project:

Jiangsu Ecological Research Project (2023003); Jiangsu Key R&D Program (Industry Foresight and Key Core Technology) Project (BE2022152); National Key R&D Project (2022YFC3204100); Jiangsu Excellence Postdoctoral Program(2024ZB312); National Natural Science Foundation of China Youth Program (42401479)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Similar Literature
  • |
  • Cited by
  • |
  • Appendix
  • |
  • Comments
    Abstract:

    Phytoplankton chlorophyll-a (Chl-a) concentration serves as a crucial indicator for assessing water eutrophication status. Conventional monitoring approaches face significant limitations: laboratory analyses are time-consuming and labor-intensive, while in-situ sensors suffer from biofouling interference, low accuracy, and high maintenance costs. Traditional satellite remote sensing techniques are unsuitable for high-precision and real-time monitoring due to incorrect atmospheric correction, technical complexity, and poor temporal resolution. The emergence of hyperspectral proximal sensing technology has effectively addressed these challenges, significantly improving Chl-a concentration monitoring efficiency. This study employed a novel portable hyperspectral proximal sensing water quality monitoring device, collecting 533 synchronized in-situ Chl-a measurements across eight lakes, reservoirs, and rivers from 2021 to 2024. High-accuracy Chl-a concentration inversion models were developed and compared through both linear regression algorithms and machine learning approaches to achieve real-time Chl-a concentration monitoring. Comparative analysis of models based on linear regression, Random Forest (RF), Extreme Gradient Boosting (XGBoost), and Support Vector Machine (SVM) algorithms revealed that the XGBoost-based model demonstrated superior performance (R2=0.87, RMSE=6.02 μg/L, MAE=3.98 μg/L). This innovative methodology enables simultaneous spectral acquisition and Chl-a concentration estimation, streamlining field monitoring procedures while reducing technical barriers and significantly enhancing operational efficiency.

    Reference
    Related
    Cited by
Get Citation
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:March 21,2025
  • Revised:April 04,2026
  • Adopted:September 25,2025
  • Online: October 31,2025
  • Published:
You are the first    Visitors
Address:No.299, Chuangzhan Road, Qilin Street, Jiangning District, Nanjing, China    Postal Code:211135
Phone:025-86882041;86882040     Fax:025-57714759     Email:jlakes@niglas.ac.cn
Copyright © Lake Science, Nanjing Institute of Geography and Lake Sciences, Chinese Academy of Sciences:All Rights Reserved
Technical Support:Beijing Qinyun Technology Development Co., Ltd.

Su Gongwang Security No. 11040202500063

     苏ICP备09024011号-2